Page 8 - AKIN COMPANY PROFILE
P. 8

BALIKESIR  POTABLE  WATER  TREATMENT  PLANT  AND
                                                          PUMPING STATIONS
                                                          Type Of Contract:    Design  Build  Contract  with  1  year
                                                                               operation supervision
                                                          Position Hold:       Project Coordinator
                                                          Average Flow:        220.000 m3/day
                                                          Max. Flow:           229.800 m3/day
                                                          Process Units:       P0  Raw  Water  Pumping  Station,
                                                          Cascade  Aeration,  Flash  Mixing,  Injection  Mixing,
                                                          Flocculation Mixing, Lamella Sedimentation (Actiflo), Micro
                                                          Sand Recirculation, Mixing Chamber, Rapid Sand Filtration,
                                                          Contact  Tank,  Treated  Water  Tank,  Backwash  Water
                                                          Recovery,  Thickener,  Filter  Press,  Reagent  Building,
                                                          Transformer  Stations,  P1  Treated  Water  Pumping  Station,
                                                          P2 Treated Water Pumping Station

                                                          PURSAKLAR POTABLE WATER TREATMENT PLANT
                                                          Type Of Contract:    Design  Build  Contract  with  1  year
                                                                               operation supervision
                                                          Position Hold:       Project Manager
                                                          Average Flow:        75.000 m3/day
                                                          Max. Flow:           90.000 m3/day
                                                          Process Units:       Raw    Water   Regulation,   Flash
                                                          Mixing,  Flocculation  Mixing,  Lamella  Sedimentation
                                                          (Multiflo),  Rapid  Sand  Filtration,  Contact  Tank,  Treated
                                                          Water  Tank,  Backwash  Water  Recovery,  Reagent  Building,
                                                          Transformer Station,


                                                          KAYAS BAYINDIR POTABLE WATER TREATMENT PLANT
                                                          Type Of Contract:    Design  Build  Contract  with  1  year
                                                                               operation supervision
                                                          Position Hold:       Project Manager
                                                          Average Flow:        30.000 m3/day
                                                          Max. Flow:           31.200 m3/day
                                                          Process Units:       Raw  Water  Pumping  Station,  Flash
                                                          Mixing,  Flocculation  Mixing,  Lamella  Sedimentation
                                                          (Multiflo),  Rapid  Sand  Filtration,  Contact  Tank,  Treated
                                                          Water  Tank,  Backwash  Water  Recovery,  Reagent  Building,
                                                          Transformer Station,


                                                          MERSIN POTABLE WATER TREATMENT PLANT
                                                          Type Of Contract:    Design  Build  Contract  with  1  year
                                                                               operation supervision
                                                          Position Hold:       Project Manager
                                                          Average Flow:        390.000 m3/day (3 Stage – 130.000
                                                                               m3/day each stage)
                                                          Process Units:       Raw    Water   Pumping    Station,
                                                          Cascade  Aeration,  Flash  Mixing,  Sedimentation  Unit
                                                          (Cyclofloc), Micro Sand Recirculation, Rapid Sand Filtration,
                                                          Contact  Tank,  Treated  Water  Tank,  Backwash  Water
                                                          Recovery, Thickener, Filter Press, Reagent Building, Chlorine
                                                          Building, Transformer Station,
   3   4   5   6   7   8   9   10   11   12   13